High volume repair and insulation treatments as effective water coning prevention method

https://doi.org/10.51890/2587-7399-2023-8-2-105-111

Abstract

Introduction. For massive carbonate reservoir with high vertical permeability and underlying water, coning of bottom water is a necessary part of development process. As an example, the way for water coning prevention using thermogelling composition for Zapadno-Hosedauskoe field is described.

Aim. The aim of investigation is planning and realization of water coning prevention pilot project. It is also necessary to determine well candidate criteria, to analyze first results, and to look for technology optimization variants.

Methods. For coning evaluation Chan’s diagnostic plots and well flow profile were used.

Results. The pilot project has been realized in three steps, based on first step results the additional well candidate criteria has determined and methodology basis for candidate search and treatments planning has developed. During second step, treatment volumes have been varying, in third step, alternative composition has been approved and repeated treatments have been done. In 2019–2022 years period 26 treatments were done, all except one were successful, oil rate increment and watercut reduction were obtained. Additional oil production due to pilot project realization is more than 120 000 tons.

Conclusions. Authors showed results of three years water coning prevention treatments pilot project, determined success well candidate criteria and estimated additional oil production.

About the Authors

A. N. Stepanov
JSC “VNIIneft”
Russian Federation

Andrey N. Stepanov — Head of direction of reservoir engineering department

10, Dmitrovskiy proezd, 127422, Moscow



G. A. Fursov
JSC “JC“RUSVIETPETRO”
Russian Federation

Grigoriy A. Fursov — Chief geologist

10, Dmitrovskiy proezd, 127422, Moscow



D. M. Ponomarenko
JSC “JC“RUSVIETPETRO”
Russian Federation

Denis M. Ponomarenko — Head of EOR and new technology division

10, Dmitrovskiy proezd, 127422, Moscow



References

1. Chaperon I. Theoretical Study of Coning Toward Horizontal and Vertical Wells in Anisotropic Formations: Subcritical and Critical Rates. — 1986. — SPE15377.

2. Leif A. Hoyland, SPE, Statoil, and Paul Papatzacos, SPE, and Sveln M. Skjaeveland, SPE, Rogaland U, Critical Rate for Water Coning: Correlation and Analytical Solution. — 1989. — SPE Reservoir Engineering, November 1989, p. 495–502.

3. Abass H. H. Colorado School of Mines, and D. M. Bass, B, D&D Inc, The Critical Production Rate in Water-Coning System. — 1988. — SPE17311.

4. Anthony E., Elaila S. , Al-Maqsseed N. , Kuwait Oil Company; M. Areekat, Baker Hughes International, Inverted ESP. Changing the Game in Water Coning Control in Water Drive Reservoirs — North Kuwait Case Study. — 2017. — SPE187292.

5. Chan K.S. Water Control Diagnostic Plots. — 1995. — SPE30775.


Review

For citations:


Stepanov A.N., Fursov G.A., Ponomarenko D.M. High volume repair and insulation treatments as effective water coning prevention method. PROneft. Professionally about Oil. 2023;8(2):105-111. (In Russ.) https://doi.org/10.51890/2587-7399-2023-8-2-105-111